Features
:
|
|
. Complies fully with
ISO standard 11146 . Measures beams from
60зн to 4.5mm . Measures wavelengths
from 180nm to 1.15зн . Provides 2000
: 1 software-controlled dynamic range . Captures
images and profiles of cw and pulsed beams . Operates
in a Microsoft WindowsTM environment
|
|
|
|
|
|
|
|
|
The WinCamTM
PCI is a camera-based beam profiler that is engineered for
ease of installation and use. It comprises a CCD camera with an
ND-4.0 absorbing neutral-density filter, a PCI board for installation
in a Pentium® PC, and software. Installation of a complete system
takes less than ten minutes. WinCam overcomes the main drawback
of camera-based systems - limited dynamic range - with EclipseTM
software that controls both camera shutter speed and camera gain
and provides a dynamic range of 2000:1. The WinCam PCI can be
placed as close as 1mm to the laser source and may be used with
either pulsed or cw lasers. A simple double-click on the computer
mouse switches between accurate two-dimensional and three-dimensional
representations of the beam profile. The area of the beam to be
displayed is mouse selectable, along with zoom ratios than can vary
from 1:1 to 8:1. Standard spectral response of the camera is
from 350nm to 1.15зн. Melles Griot can provide the camera without
a cover glass, which drops the lower limit to 190nm. The standard
camera is supplied without a window, but includes the fitted ND-4.0
wedged filter. This eliminates interference fringes generated in
the window by coherent sources. The system is also available with
a window for extra protection. The standard spectral response
is from 250nm to 1150nm. Systems for use at wavelengths down to
190nm are available by special order.
|
|
|
|
|
|
|
Specifications : WincamTM
PCI Beam Profilers
|
|
Measurements
:
|
Cw
or pulsed laser beam profile, diameter,
centroid, geometrical center, ellipticity,
and orientation.
|
|
Diameter
Profiles :
|
Gaussian,
second moment, equivalent knife-edge, and
top hat
|
|
Display
:
|
Profiles : 2-dimensional and 3-dimensional(with autorotate) Zoom Ratios :
1:1, 2:1, 4:1, 8:1, autofit Functions
: Shutter, gain,
file/frame, autocapture or sync capture (for
pulsed lasers), auto background subtraction
|
|
System
Requirements :
|
100-MHz Pentium-class PC with minimum 8-MB RAM. PCI slot, and SVGA(600 x
800) monitor
|
|

|
|
|
|
|
|
|

|
|
|
|
|
|

|
|
|
|
|
|
|
Laser
Accessories
|
Beam
Profilers
|
|
BeamscopeTM
Beam Profilers
|
|
|
|
|
|
|
|
Specifications : BeamscopeTM
Beam Profilers
|
|
Beam
Diameter :
|
0.5зн
to 25mm(depending on slit configuration and head)
|
|
Measurements
:
|
Cw
or pulsed(>500Hz) beam profile, diameter, centroid,
geometrical center, ellipticity, beam divergence
|
|
Diameter
Profiles :
|
Gaussian, second moment, knife-edge, and top hat
|
|
Display
:
|
2-dimensional profiles and 3-dimensional reconstructions, pass/fail color indication
on measured parameters, averages and standard deviations
of measured parameters
|
|
Detector
Wavelength Range :
|
Silicon
: 190-1100nm Germanium : 800-1800nm Indium-arsenide
: 1500-4000nm II-VI Detector : 4-12зн
|
|
Resolution
:
|
0.05зн
or 0.1%, whichever is greater
|
|
Dynamic
Range :
|
55dB
|
|
Position
Measurement :
|
Resolution
: ±1% or 1зн, whichever is greater Accuracy
: ±1% or ±1зн, whichever is greater
|
|
Minimum
System Requirements :
|
100-MHz
Pentium-class PC with 4MB hard disk space, minimum
8-MB RAM, one full-size ISA slot, and SVGA (600 x 800)
color monitor
|
|
M2
Attachment :
|
17.5-mm
clear aperture
|
|
|
|
|
|
|

|
|
|
|
|
|
|