*Sub Menu l

 HASO  / HASO UV / HASO NIRHASO OEM

  < go to top

 

 

 

 

 

 

1.HASO II  /   2.HASO UV  /   3.HASO NIR  /  4.HASO OEM

 

Spectral Products

Wavefront Sensor for Integrators

HASOII

 

 

 

 

. Beams analysis in phase and intensity

. Components and systems characterization

. Focal length, MTF and point spread function measurement

. Adjustment, mounting alignment

. Active and adaptive optics

 

. Achromatic and non sensitive to the coherence

. Display and calculation in real time

. High spatial resoultion

. Strong divergent and convergent beams analysis

. Wave fronts measurement in absolute or relative mode

 

Optical wavefront sensor

These wavefront sensors (Shack-Hartmann type)

allow to obtain a map of local slopes of the analysed

wavefront with the help of a microlenses array.

This principle used for a long time in astronomy was

amply improved as well on hardware as on software.

The CCD detectors reached the maturity and the

necessary quality/price ratio to certify an

irreproachable metrology with moderate prices;

the fabrication of microlenses arrays has become reliable.

The software innovations of Imagine Optic allow to use

trough optimal way this simple and direct measurement.

 

 

 

 

HASO 16

HASO 32

HASO 64

Aperture dimension

2.5 x 2.5 mm

5 x 5 mm

12 x 12 mm

Number of sub-apertures dedicated
for analysis

16 x 16

32 x 32

64 x 64

Tilt dynamic range

> ±3° (260 ル)

> ±3° (520 ル)

> ±3° (1200 ル)

Focus dynamic range

±0.025 m to ±…

(50 ル)

±0.025 m to ±…

(200 ル)

±0.04 m to ±…

(200 ル)

Repeatability (rms)

< ル / 200

Wavefront measurement accuracy
in absolute mode rms(2)

ル / 100

Wavefront measurement accuracy
in relative mode rms(3)

ル / 150

Tilt measurement sensitivity

6 レrad

3 レrad

1 レrad

Focus measurement sensitivity

5.10m

10m

5.10m

Spatial resolution

~ 160 レm

~ 160 レm

~ 190 レm

Max acquisition frequency

955 Hz

77 Hz

20 Hz (opt. 40 Hz)

Processing frequency

8-40 Hz

4-20 Hz

2-10 Hz

Working wavelength

350-1100 nm

Calibrated wavelength band

400-600 nm / 500-700 nm / 650-900 nm / 800-1100 nm

Extended calibrated wavelength band

400-700 nm / 500-900 nm / 650-1100 nm

Working temperature

15 - 30 ”

Dimensions / weight

90 x 100 x 130 mm

/ 1125 g

80 x 90 x 100 mm

/ 980 g

90 x 100 x 130 mm

/ 1200 g

Power supply

5, -12, 12 V / 6 W

5, -12, 12 V / 6 W

+5,-5,-15,28 V / 20 W

 

these data are given for the central wavelength of the band defined

(1) other configurations are available: HASO 50 for instance.

(2) wavefront seen by the analyser. performance kept on the whole band

(3) difference between the real wavefront and a reference wavefront obtained in similar conditions (10 ル of shift max).

 

 

Spectral Products

Wavefront Sensors

HASO UV

 

HASO UV 25

HASO UV 50

Aperture dimension

4.9 x 4.9 mm

11.7 x 11.7 mm

Number of sub-apertures dedicated for analysis

25 x 25

50 x 50

Dynamic meas. range by sub pupil without tilt and focus

~ ±3 ル

~ ±3 ル

Tilt dynamic range

till ±1.5°

till ±1.5°

Focus dynamic range (1)

±0.055 m to ±…

±0.085 m to ±…

Maximum operating aperture (half angle sinメ)

0.04 (max)

0.07 (max)

Repeatability (rms)

~ 1.5 nm

~ 1.5 nm

Wavefront measurement accuracy in absolute mode rms(2)

~ 3.5 nm

~ 3.5 nm

Wavefront measurement accuracy in relative mode rms(3)

~ 2.5 nm

~ 2.5 nm

Tilt measurement accuracy

1.5 レrad

0.5 レrad

Focus measurement accuracy

5.10m

2.5,10m

Spatial resolution

~ 200 レm

~ 230 レm

Acquisition frequency / Processing frequency

~ 77 Hz / ~ 4 Hz

~ 20 Hz / ~ 3 Hz

Wavelength

244 - 350 nm

Working temperature

15 - 30” / 5 - 45”

 

Note 1: For the central wavelength: 150 ル for the HASO UV 25, 470 ル for the HASO UV 50.

Note 2: wavefront directly measurement by the wavefront sensor (no added lens).

Note 3: difference between a referenced wavefront and the measured wavefront, in a range < 10 ル.

 

 

Spectral Products

Wavefront Sensors

HASO NIR

 

HASO NIR 32

HASO NIR 40

Aperture dimension

4.8 x 6.4 mm

4.8 x 6.4 mm

Number of sub-apertures dedicated for analysis

25 x 32

30 x 40

Dynamic meas. range by sub pupil without tilt and focus

~ ±2 ル

~ ±2 ル

Tilt dynamic range

till ±3°

till ±5°

Focus dynamic range (1)

±0.025 m to ±…

±0.016 m to ±…

Maximum operating aperture (half angle sinメ)

0.11 (max)

0.17 (max)

Repeatability (rms)

~ ル / 80

~ ル / 70

Wavefront measurement accuracy in absolute mode rms(2)

~ ル / 40

~ ル / 35

Wavefront measurement accuracy in relative mode rms(3)

~ ル / 60

~ ル / 50

Tilt measurement accuracy

8 レrad

12 レrad

Focus measurement accuracy

10.10m

15.10m

Spatial resolution

~ 190 レm

~ 160 レm

Acquisition frequency / Processing frequency

~ 20 Hz / ~ 4 Hz (depending of the configuration)

Wavelength

1500 - 1600 nm

Working temperature

15 - 30” / 5 - 45”

 

* : all specifications given with an average operating mode of 10 acquisitions.

Note 1: Central wavelengths: 120 ル for HASO NIR 32, 180 ル for HASO NIR 40.

Note 2: Wavefront directly measurement by the wavefront sensor (no added lens).

Note 3: Difference between a referenced wavefront and the measured wavefront, in a range < 10 ル.

 

 

 

 

Wavefront acquisition (standard software)

Absolute (factory calibration) or referenced (user calibration) mode - one-shot or flying acquisition - camera signal

- background signal: save and subtract in real time - for the sensor adjustment: tilt visualization; manual adjustment

of integration time.

Wavefront reconstruction (standard software)

Wavefront display (unit in microns or lambda): 3D, 2D projection, fringes mode, XY profile, save function

(text or excel format, comments) - display in real time with or without tilt and/or focus and/or 3rd order aberrations -

intensity display: 3D, 2D projection, XY profile, save function (text or excel format, comments) - reconstruction:

zonal or modal (Zernike or Legendre) - pupil shape: with or without central occultation.

Wavefront : other tools (standard software)

Location (x y z) of the focus point - polynom coefficient display (unit in microns or lambda), historic function:

display of the time changes of 4 coef. - local slopes display : with or without tilt and focus, zoom, RMS and PV

of the slopes - pupil calculation : automatic or manual (save and load functions) - spot diagram in real time

for various observation positions.

Point Spread Function measurement (PSF software)

PSF display : 3D, 2D projection, XY profile - parameters : best focus plane, user specified plane,

focal plane of ideal lens - zoom (1 to 8) - Strehl ratio - numerical value in table - save and load functions

(text or excel format, comments).

MTF measurement (MTF software)

MTF display: 2D, x profile (user choice) - parameters: best focus plane, user specified plane, focal plane

of ideal lens - zoom (1 to 8) - historic function: display of the time change of a specified frequency - save

and load functions (text or excel format, comments).

Laser characterisation (M² software)

Beam location, dimension and position of the waist - display of the beam shape - M² calculation - calculation

of intensity shape in any plane - save and load functions (text or excel format, comments).

Coupling efficiency (Preliminary)

Beam location, dimension and position of the waist - display of the beam shape - calculation of intensity shape

in any plane, and comparison with dimension and aperture of the fibre - save and load functions

(text or excel format, comments).

Dynamic library

dll in C or VI for Labview : all the software functions to build specific soft applications.

Spectral Products

Wavefront Sensors

HASO OEM

 

. Designed to fit easily your application

. Optical characterisation bench

. Laser characterisation toolkit

. Optical process optimisation

. Active optics systems

. Ophthalmologic applications

 

. Non sensitive to coherence

. Monochromatic wavefront analysis

. Display and calculation in real time

. High spatial resolution

. wavefronts measurement in absolute or relative mode

. Small and light, easy to integrate

. Low cost sensor

 

 

 

 

 

 

 

 

HASO 32

HASO 64

Aperture dimension

3.6 x 3.6 mm

6.7 x 6.7 mm

Number of sub-apertures dedicated for analysis

32 x 32

64 x 64 (1)

Tilt dynamic range

> ±3° (400 ル)

> ±3° (700 ル)

Focus dynamic range

±0,015 m to ±… (400 ル)

±0,02 m to ±… (800 ル)