The Standard Mini-Chrom(MC) is a low
cost, in-line, Fastie-Ebert monochromator available
in six wavelength ranges covering the ultraviolet, visible
and near infrared. The Standard Mini-Chrom is a manual
unit which utilizes a micrometer for wavelength selection
and readout. Turning the micrometer head causes, via
a precision sine bar drive, rotation of the diffraction
grating which positions the desired wavelength at the
exit slit.
Wavelength in nanometers(nm) is read
directly from the micrometer head in models 01, 02,
03, and 04. Near infra-red models (05 and 06) require
the micrometer reading to be doubled, to 2nm per division,
for wavelength selection and readout.
Standard Mini-Chroms are used in variety
of applications that require an inexpensive, small yet
high performance monochromator. They are used in physics,
chemistry, engineering and the life sciences for research,
development and teaching.
|

STANDARD
MINI-CHROM
|
|
|
|
|
|
|
|

|
|
Standard
mini-chrom monochromator
A compact, in-line, f/3.9 Fastie-Ebert
monochromator with a 74mm focal length. Includes a replicated
ruled or holographic grating, a set of 300レ slits and
an instruction manual. Wavelength selection is read
directly from the micrometer in models 01, 02, 03 and
04. For models 05 and 06, the micrometer reading must
be doubled.
Dimensions : 150 x 59 x 49mm Weight
: 0.5kg (1.1lbs)
|
|

|
|
|
|
|
|
|
|
|
|
|
|
|
The Digital Mini-Chrom (DMC) is a
manually operated monochromator that utilizes a dial
for wavelength selection. Rotation of the dial causes,
via a precision lead screw/sine bar mechanism, rotation
of the diffraction grating which positions the selected
wavelength at the exit slit.
Wavelength is read directly in nanometers(nm)
from a counter on models 01, 02, 03 and 04. Near infra-red
models (05 and 06) require the micrometer reading to
be doubled, to 2nm per division, for wavelength selection
and readout.
Digital Mini-Chroms are used in a
variety of applications that require a small, high performance
monochromator coupled with the ease of operation and
convenience of an integral wavelength readout.
As with the Standard Mini-Chrom, the
Digital model 03 is available with a comparator and
a reticle for use a hand held spectrograph.
Wavelength readability The
wavelength on all Digital Mini-Chroms can be selected
and read to 0.2nm.
|

DIGITAL
MINI-CHROM
|
|
|
|

|
|
Digital
mini-chrom monochromator
A compact, in-line, f/3.9
Fastie-Ebert monochromator with a 74mm focal
length. Includes a replicated ruled or holographic
grating, a set of 300レ slits and an instruction
manual. Wavelength selection is via a dial
that provides wavelength readout on a four
digit counter. For models 05 and 06, the
four digit counter reading must be doubled.
Dimensions : 139 x 59
x 49mm Weight : 0.7kg (1.5 lbs)
|
|

|
|
|
|
|
|
|
|
|
|
|
|
|
|
The Scanning Mini-Chrom monochromator(SMC)
is designed to be driven stepping or servo-controlled
motors. No wavelength readout is provided. All models
utilize a precision lead screw/sine bar mechanism to
rotate the diffraction grating and sequentially position
the selected wavelengths(s) at the exit slit. Rotation
of the drive shaft in a clockwise direction proportionately
increases the wavelength of radiation at the exit slit.
Scanning Mini-Chroms are used in applications
requiring either single or repetitive scans of wavelength
intervals or the sequential selection of discrete wavelengths.
Scanning Mini-Chroms are calibrated in nanometers (nm)
per drive shaft revolution.
Wavelength calibration Wavelength
calibration of the Scanning Mini-Chrom can be accomplished
by using either the trip point of the low limit sensor
or zero order light as reference points. The position
of the low limit sensor, in nanometers, is provided
with each instrument. This value can be added to the
computer command when a scan is initiated.
|

SCANNING
MINI-CHROM
|
|
|
|

|
|
Scanning
mini-chrom monochromator
A compact, in-line, f/3.9
Fastie-Ebert monochromatior with a 74mm
focal length. Includes a replicated ruled
or holographic grating, a set of 300レ slits,
a precision lead screw/sine bar drive, high
and low limit switches (dual photosensors),
a wiring harness with 5-pin connector and
an instruction manual. Wavelength selection
via an external controller(not included).
No wavelength readout is provided.
Dimensions : 95 x 59 x
49mm Weight : 0.45kg (1.0 lb)
|
|

|
|
|
|
|
|
|
|
|
|
Scanning
Digital Mini-Chrom
|
|
|
|
|
|
|
|
|
The Scanning Digital Mini-Chrom(SDMC)
incorporates the capabilities of the Scanning and Digital
Mini-Chroms in a single housing. In addition, the SDMC
includes and intergral stepping motor, allowing it to
be controlled by a calibrated driver such as the CB-3.
The SDMC is similar to the Digital Mini-Chrom in that
it includes a four digit counter for wavelength readout
and a dial for manual wavelength selection. Like other
Mini-Chorms, the SDMC utilizes a lead screw/sine bar
mechanism to rotate the grating.
Dual photosensors that function as
high and low limit switches are included for use in
the scanning mode.
The Scanning Digital Mini-Chrom can
be used for all applications that require the convenience
of a built-in wavelength readout as well as applications
that require scanning to a selected wavelength or over
a wavelength interval. A 15 pin connector that can be
connected directly to the CB-3 controller allows access
to the integral stepping motor and limit switches.
|

SCANNING
DIGITAL MINI-CHROM
|
|
|
|

|
|
Scanning
digital mini-chrom monochromator
A compact, in-line, f/3.9
Fastie-Ebert monochromatior with a 74mm
focal length. Includes a replicated ruled
or holographic grating, a set of 300レ slits
and an instruction manual. Wavelength readout
is via a four digit counter. Wavelength
selection can be accomplished manually,
via a dial or by the integral stepping motor.
Includes a precision lead screw/sine bar
drive, high and low limit switches
(dual photosensors) and a 15pin connector.
For models 05 and 06, the four digit counter
reading must be doubled.
Dimension : 197 x 59 x
49mm Weight : 0.9kg (1.9lbs)
|
|

|
|
|
|
|
|
|
|
|
Spectral
Products
|
Monochromators
|
|
Monochromators
for the UV-VIS-IR
|
|
|
|
|
|
|
|
Model
272
|
|
. High throughput,
f/2 . Corrected holographic gratings .
Micrometer adjustable bilateral slits
- . curved
entrance type is standard . Compact
and operable .
in any attitude . Many accessories
available
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
218
|
|
. Patented criss-crossed
design . Vaccum-tight aluminum housing .
Patented "snap-in" grating .
PDA and CCD adaptable
|
|
|
|
|
|
|
|
|
Model
2035
|
|
. Single or dual grating
holder(s) . Optional corrective imaging
optics . Multiple slit locations .
PDA and CCD adaptable . Available
in double . monochromator
configuration
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
270
|
|
. Bidirectional stepping
motor . Easy grating interchange .
Stepping rates from 0.005 to .
2nm per second . Remote drive
capability
|
|
|
* 5-10レslits
at 3131 ( (subject to diffraction limits)
|
|
|
|
|
|
|

|
|
|
|
|
|
|
Model
207
|
|
. High throughput,
low f/no. . Corrective imaging optics
available . Patented "snap-in"
gratings . Multiple slit locations .
PDA and CCD adaptable
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
2061 A/B
|
|
. High throughput,
low f/no. . High resolution .
Low stray light . Corrective imaging
optics available . PDA and CCD adaptable .
Multiple slit locations
|
|
|
|
|
|
|
|
|
Model
209
|
|
. High resolution,
low f/no. . Low stray light .
Prism predisperser adaptable . PDA
and CCD adaptable . Multiple slit
locations
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
2062
|
|
. Ultra high resolution .
Prism predisperser adaptable . Accommodates
Echelle gratings . Double pass, double
dispersion .
available . Temperature controllable .
Patented "snap-in" gratings .
PDA and CCD adaptable
|
|
|
5-10レslits at 313((subject to diffraction
limits)
|
|
|
|
|
|
|
|
Spectral
Products
|
Monochromators
|
|
Monochromators
for the VUV-UV-VIS
|
|
|
|

|
|
|
|
|
|
|
Model
234/302
|
|
. Aberration corrected
optical system . Compact, rugged,
lightweight . Available with multiple
ports . PDA and CCD adaptable** .
Double monochromator .
configuration available
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
235
|
|
. Stainless steel
vaccum chamber . Compact optical
design . Easy grating exchange .
PDA and CCD adaptable**
|
|
|
|
|
|
|
|
|
Model
231
|
|
. Increased work space .
Stainless steel vaccum chamber .
Field proven stability . PDA and
CCD adaptable**
Seya-Namioka
design provides increased work space
and best resolution due to 70.25°
included angle.
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
310G
|
|
. Extreme UV Spectrometer .
Easy grating exchange . Adjustable
angle of incidence, .
84-88 degrees . Single and
multi-channel detection** .
UHV versions available
|
|
|
** May
require microchannel plate intenstifer, *
5-10レ slits at 3131((subject to diffraction limits)
|
|
|
|
|
|
|

|
|
|
|
|
|
|
Model
225 NOVA
|
|
. High resolution .
Minimum polarization and astigmatism .
UHV stainless steel vaccum chamber .
CCD adaptable**
Focusing
and wavelength adjustment is accomplished
by a patented drive system located outside
the HUV chamber.
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
209V
|
|
. High resolution .
Low stray light . Multiple slit locations .
Patented "snap-in" gratings .
PDA or CCD adaptable**
|
|
|
|
|
|
|
|
|
Model
2252
|
|
. High resolution .
Patented auto focus .
wavelength drive . UHV stainless
steel vaccum .
chamber . 180→optical path
|
|

|

|
|
|
|
|
|
|
|
|

|
|
Model
2253
|
|
. High resolution .
UHV stainless steel vaccum chamber .
Multiple port locations . Isolated
input and output . Grating turret .
PDA and CCD adaptable**
|
|
|
** May
require microchannel plate intensifier, *
5-10レ slits at 3131((subject to diffraction limits)
|
|